KERN & sohn scale error codes

15 series · 144 error codes

On KERN devices, error codes vary by series. The ALJ, ALS, PLJ, PLS, HFD and PFB series have separate error messages for zeroing, tare, capacity and calibration.

Err 1 Invalid date HFD · Err 1 indicates an invalid date on the KERN & Sohn HFD. Err 2 Invalid time HFD · Err 2 indicates an invalid time on the KERN & Sohn HFD. Err 4 Zeroing range exceeded HFD · Err 4 indicates the zeroing range exceeded on the KERN & Sohn HFD. Err 5 Keypad error HFD · Err 5 indicates a keypad error on the KERN & Sohn HFD. Err 6 A/D converter range error HFD · Err 6 indicates an A/D converter range error on the KERN & Sohn HFD. Err 7 Percent reference value too low HFD · Err 7 indicates a percent reference value that is too low on the KERN & Sohn HFD. Err 8 Wrong calibration weight HFD · Err 8 indicates a wrong calibration weight on the KERN & Sohn HFD. Err 9 Unstable weighing value HFD · Err 9 indicates an unstable weighing value on the KERN & Sohn HFD. Err 10 No WLAN connection HFD · Err 10 indicates no WLAN connection on the KERN & Sohn HFD. Err 11 Communication setting error HFD · Err 11 indicates a communication setting error on the KERN & Sohn HFD. Err 12 Totalizing limit exceeded HFD · Err 12 indicates the totalizing limit exceeded on the KERN & Sohn HFD. Err 15 Gravity constant out of range HFD · Err 15 indicates a gravity constant out of range on the KERN & Sohn HFD. Err 17 Tare range exceeded HFD · Err 17 indicates the tare range exceeded on the KERN & Sohn HFD. Err 19 Zero point cannot be ınitialized HFD · Err 19 indicates the zero point cannot be initialized on the KERN & Sohn HFD. --ol-- Maximum load exceeded HFD · --ol-- indicates the maximum load exceeded on the KERN & Sohn HFD. --lo-- Underload HFD · --lo-- indicates an underload on the KERN & Sohn HFD. Fail Calibration error HFD · Fail indicates a calibration error on the KERN & Sohn HFD. Fail h Calibration error HFD · Fail h indicates a calibration error on the KERN & Sohn HFD. Fail l Calibration error HFD · Fail l indicates a calibration error on the KERN & Sohn HFD. Ba lo / lo ba Battery empty HFD · Ba lo / lo ba indicates an empty battery on the KERN & Sohn HFD. Err 3 Calibration error PFB · Err 3 indicates that a wrong adjustment weight was used during calibration on the KERN & Sohn PFB. Err 4 Zero range exceeded PFB · Err 4 indicates the zero range exceeded on the KERN & Sohn PFB. Err 5 Keypad / ınvalid ınput error PFB · Err 5 indicates a keypad / invalid input error on the KERN & Sohn PFB. Err 6 A/D converter range error PFB · Err 6 indicates an A/D converter range error on the KERN & Sohn PFB. Err 7 Percent reference weight too low PFB · Err 7 indicates a percent reference weight that is too low on the KERN & Sohn PFB. Err 8 External calibration weight unsuitable PFB · Err 8 indicates an unsuitable external calibration weight on the KERN & Sohn PFB. OL Maximum capacity exceeded PFB · OL indicates that the maximum capacity was exceeded on the KERN & Sohn PFB. NULL / underload display Weighing pan missing / underload PFB · NULL indicates a missing weighing pan / underload on the KERN & Sohn PFB. ERR01 Unstable weighing or zeroing error ALJ · The weighing value is not stable or the device cannot be zeroed. ERR02 Calibration environment error ALJ · Environmental conditions are not stable enough during calibration. ERR03 Wrong calibration weight ALJ · An unsuitable weight was used for calibration. ERR04 Sample weight too low or unstable ALJ · The single-piece sample weight used for piece counting is too low or unstable. ERR05 Unstable weighing during data transfer ALJ · Data cannot be sent because the weighing value is not stable. ERR06 Unstable weighing during density measurement ALJ · The weighing value is not stable during density determination. ERR07 Invalid data reading ALJ · Invalid data was detected in a function such as piece counting or density measurement. ERR08 Internal calibration error ALJ · The internal calibration could not be completed. UNLOAD Weighing range lower limit error ALJ · The device does not detect the expected minimum weighing load. ERR01 Unstable weighing or zeroing error ALS · The weighing value is not stable or the device cannot be zeroed. ERR02 Calibration environment error ALS · Environmental conditions are not stable enough during calibration. ERR03 Wrong calibration weight ALS · An unsuitable weight was used for calibration. ERR04 Sample weight too low or unstable ALS · The single-piece sample weight used for piece counting is too low or unstable. ERR05 Unstable weighing during data transfer ALS · Data cannot be sent because the weighing value is not stable. ERR06 Unstable weighing during density measurement ALS · The weighing value is not stable during density determination. ERR07 Invalid data reading ALS · Invalid data was detected in a function such as piece counting or density measurement. ERR08 Internal calibration error ALS · The internal calibration could not be completed. UNLOAD Weighing range lower limit error ALS · The device does not detect the expected minimum weighing load. ERR01 Unstable weighing or zeroing error PLJ · The weighing value is not stable or the device cannot be zeroed. ERR02 Calibration environment error PLJ · Environmental conditions are not stable enough during calibration. ERR03 Wrong calibration weight PLJ · An unsuitable weight was used for calibration. ERR04 Sample weight too low or unstable PLJ · The single-piece sample weight used for piece counting is too low or unstable. ERR05 Unstable weighing during data transfer PLJ · Data cannot be sent because the weighing value is not stable. ERR06 Unstable weighing during density measurement PLJ · The weighing value is not stable during density determination. ERR07 Invalid data reading PLJ · Invalid data was detected in a function such as piece counting or density measurement. ERR08 Internal calibration error PLJ · The internal calibration could not be completed. UNLOAD Weighing range lower limit error PLJ · The device does not detect the expected minimum weighing load. ERR01 Unstable weighing or zeroing error PLS · The weighing value is not stable or the device cannot be zeroed. ERR02 Calibration environment error PLS · Environmental conditions are not stable enough during calibration. ERR03 Wrong calibration weight PLS · An unsuitable weight was used for calibration. ERR04 Sample weight too low or unstable PLS · The single-piece sample weight used for piece counting is too low or unstable. ERR05 Unstable weighing during data transfer PLS · Data cannot be sent because the weighing value is not stable. ERR06 Unstable weighing during density measurement PLS · The weighing value is not stable during density determination. ERR07 Invalid data reading PLS · Invalid data was detected in a function such as piece counting or density measurement. ERR08 Internal calibration error PLS · The internal calibration could not be completed. UNLOAD Weighing range lower limit error PLS · The device does not detect the expected minimum weighing load. Err 19 Zero point cannot be ınitialized PFB · Err 19 indicates that the zero point could not be initialized on the KERN & Sohn PFB. CAL But Adjustment (calibration) required ALJ · CAL But indicates that the KERN & Sohn ALJ balance needs to be adjusted (calibrated). CAL But Adjustment (calibration) required ALS · CAL But indicates that the KERN & Sohn ALS balance needs to be adjusted (calibrated). CAL But Adjustment (calibration) required PLJ · CAL But indicates that the KERN & Sohn PLJ balance needs to be adjusted (calibrated). CAL But Adjustment (calibration) required PLS · CAL But indicates that the KERN & Sohn PLS balance needs to be adjusted (calibrated). ERR H Hardware error ABS · The balance has detected a fault in its electronic hardware. ERR C Zero shift during adjustment ABS · The zero point shifted too much during adjustment. CAL D Unstable display during adjustment ABS · The display did not settle on a stable value during adjustment. ERR N Numeric ınput error ABS · The numeric value entered is not valid, for example a wrong password. ERR W Wrong application ABS · The selected application or function cannot be used in this state. COM ERR Wrong remote command ABS · A command from the computer or connected device was not recognised. - OL Pan not installed ABS · The balance has detected that the weighing pan is missing. OL Overload ABS · The load on the pan exceeds the weighing capacity. BUSY Pan loaded at adjustment start ABS · Objects were on the weighing pan when adjustment was started. ERR H Hardware error ABJ · The balance has detected a fault in its electronic hardware. ERR C Zero shift during adjustment ABJ · The zero point shifted too much during adjustment. CAL D Unstable display during adjustment ABJ · The display did not settle on a stable value during adjustment. ERR N Numeric ınput error ABJ · The numeric value entered is not valid, for example a wrong password. ERR W Wrong application ABJ · The selected application or function cannot be used in this state. COM ERR Wrong remote command ABJ · A command from the computer or connected device was not recognised. - OL Pan not installed ABJ · The balance has detected that the weighing pan is missing. OL Overload ABJ · The load on the pan exceeds the weighing capacity. BUSY Pan loaded at adjustment start ABJ · Objects were on the weighing pan when adjustment was started. CAL E2 Zero shift during adjustment ABT · The zero point shifted too much during adjustment. CAL E3 Deviation in external adjustment ABT · The measured values deviated too much during adjustment with an external weight (PCAL). CAL E4 Deviation during adjustment ABT · The measured values deviated strongly during adjustment. Err 20 Invalid value entry ABT · The value or decimal setting entered is not valid. Err 24 Power voltage error ABT · The supply voltage to the balance is not correct. o-Err Weighing range exceeded PNJ · The load on the pan exceeds the weighing capacity. u-Err Insufficient preload PNJ · The balance does not detect the expected preload, for example the pan is missing. 3-Err Pan loaded during adjustment PNJ · There was a load on the pan during adjustment. 4-Err High deviation in ınternal adjustment PNJ · The new internal adjustment differs by more than 1 % from the previous one. A-Err Internal adjustment mechanism faulty PNJ · The automatic mechanism that moves the internal adjustment weight is faulty. b-Err Unsuitable ambient conditions PNJ · The balance asks for the ambient conditions to be checked. C-Err Clock error PNJ · The balance's internal clock is faulty. d-Err Electronics damaged PNJ · Damage has been detected in the balance electronics. L-Err Reference weight too light PNJ · The weight placed for parts counting or percentage weighing is too light. Err 710 Unstable environment PNJ · Adjustment could not be completed because ambient conditions were unstable. o-Err Weighing range exceeded PES · The load on the pan exceeds the maximum weighing range. u-Err Below minimum range PES · The measured value has fallen below the minimum weighing range. L-Err Reference weight too low PES · The sample placed as reference in parts counting is too light. t-Err Totalizing step error PES · The [S] key was pressed too early during totalizing. c-Err System error PES · The balance reports a system error (c-Err). b-Err System error PES · The balance reports a system error (b-Err). d-Err System error PES · The balance reports a system error (d-Err). 1-Err Adjustment weight too light PES · The adjustment weight used is too light for adjustment. 2-Err High deviation in adjustment test PES · The deviation in the adjustment test with an external weight is above 1 %. r-Err Uncertainty value too high PES · The measurement uncertainty entered for the external adjustment weight exceeds the allowed limit. o-Err Weighing range exceeded PEJ · The load on the pan exceeds the maximum weighing range. u-Err Below minimum range PEJ · The measured value has fallen below the minimum weighing range. L-Err Reference weight too low PEJ · The sample placed as reference in parts counting is too light. t-Err Totalizing step error PEJ · The [S] key was pressed too early during totalizing. c-Err System error PEJ · The balance reports a system error (c-Err). b-Err System error PEJ · The balance reports a system error (b-Err). d-Err System error PEJ · The balance reports a system error (d-Err). 1-Err Adjustment weight too light PEJ · The adjustment weight used is too light for adjustment. 2-Err High deviation in adjustment test PEJ · The deviation in the adjustment test with an external weight is above 1 %. 3-Err Pan loaded during ınternal adjustment PEJ · There was a load on the pan during internal adjustment. 4-Err High deviation in ınternal adjustment PEJ · The deviation measured in internal adjustment is above 1 %. A-Err Internal adjustment ended faulty PEJ · The internal adjustment did not finish correctly. ERR H Hardware error ACS · The balance has detected a fault in its electronic hardware. ERR C Zero shift during adjustment ACS · The zero point shifted too much during adjustment. CAL D Unstable display during adjustment ACS · The display did not settle on a stable value during adjustment. ERR N Numeric ınput error ACS · The numeric value entered is not valid, for example a wrong password. ERR W Wrong application ACS · The selected application or function cannot be used in this state. COM ERR Wrong remote command ACS · A command from the computer or connected device was not recognised. - OL Pan not installed ACS · The balance has detected that the weighing pan is missing. OL Overload ACS · The load on the pan exceeds the weighing capacity. BUSY Pan loaded at adjustment start ACS · Objects were on the weighing pan when adjustment was started. ERR H Hardware error ACJ · The balance has detected a fault in its electronic hardware. ERR C Zero shift during adjustment ACJ · The zero point shifted too much during adjustment. CAL D Unstable display during adjustment ACJ · The display did not settle on a stable value during adjustment. ERR N Numeric ınput error ACJ · The numeric value entered is not valid, for example a wrong password. ERR W Wrong application ACJ · The selected application or function cannot be used in this state. COM ERR Wrong remote command ACJ · A command from the computer or connected device was not recognised. - OL Pan not installed ACJ · The balance has detected that the weighing pan is missing. OL Overload ACJ · The load on the pan exceeds the weighing capacity. BUSY Pan loaded at adjustment start ACJ · Objects were on the weighing pan when adjustment was started. PLS.CAL Unload pan for automatic adjustment ACJ · There was a load on the pan when automatic internal adjustment (PSC) was due to start. Err lo Adjustment weight too small EWJ · The adjustment weight measured during adjustment was smaller than expected. Err hi Adjustment weight too large EWJ · The adjustment weight measured during adjustment was larger than expected. Err 3 Adjustment error EWJ · Internal adjustment could not be completed. Err 4 Zero range exceeded at power-on EWJ · The load on the pan was outside the zero setting range when the balance was switched on. Err 6 Measuring signal out of range EWJ · The value read by the analog-to-digital converter is outside the valid range. Err 7 Percent reference too small EWJ · The reference weight placed for percent weighing is too small. Err 19 Zero point drift EWJ · The zero point of the balance has drifted beyond the allowed limit. Err E EPROM memory error EWJ · The balance has detected an error in its EPROM memory. ---- Maximum load exceeded EWJ · The load on the pan exceeds the weighing capacity.