RADWAG scale error codes

11 series · 35 error codes

On RADWAG series, error codes vary by device family. Select the device series to see the meaning of the code and the checks you can make.

Err2 Outside zeroing range WTC 600 · Err2 indicates that the zeroing range was exceeded on the RADWAG WTC 600. Err3 Outside tare range WTC 600 · Err3 indicates that the tare range was exceeded on the RADWAG WTC 600. Err4 Calibration weight / starting mass out of range WTC 600 · Err4 indicates that the calibration weight / starting mass is out of range on the RADWAG WTC 600. Err5 Battery error WTC 600 · Err5 indicates that the internal battery is damaged (single piece weight too low in older software versions). Err8 Process timeout WTC 600 · The tare, zeroing, initial mass or calibration process could not be completed in time. null Zero value from converter WTC 600 · null reports a zero value from the converter on the RADWAG WTC 600. FULL2 Weighing range exceeded WTC 600 · FULL2 reports that the weighing range is exceeded on the RADWAG WTC 600. LH Initial mass error WTC 600 · LH reports an initial mass error on the RADWAG WTC 600. 5-FULL Totalizing display capacity exceeded WTC 600 · 5-FULL reports that the totalizing display capacity is exceeded on the RADWAG WTC 600. Err2 Zeroing range error WLC · The value is outside the permitted zeroing range. Err3 Tare range error WLC · The value is outside the permitted tare range. Err4 Calibration or ınitial mass error WLC · The calibration weight or initial mass is outside the accepted range. Err5 Battery error WLC · Err5 indicates that the internal battery is damaged (single piece weight too low in older software versions). Err8 Process timeout WLC · The tare, zeroing or adjustment operation could not be completed in time because stability was not achieved. Err9 Internal weight mechanism timeout WLC · The lifting or lowering of the internal calibration weight was not completed in the expected time. NULL A/D zero value error WLC · A zero value is being received from the A/D converter. FULL2 Measuring range exceeded WLC · The measured value exceeds the displayable range of the device. LH Initial mass error WLC · The initial mass on the platform is outside the permitted range. 5-FULL Total display range exceeded WLC · The totalizing result exceeds the displayable range. Er1 Hi Initial or calibration mass out of range AS · The initial or calibration mass is outside the permitted range. Er2 nuLL A/D lower range error AS · The A/D measurement value is below the lower operating range. Er3 FuL1 A/D upper range error AS · The A/D measurement value has exceeded the upper operating range. Er4 FuL2 Maximum capacity exceeded AS · The weighing value exceeds the maximum capacity of the device. Er5 rout Mass value outside permitted range AS · The entered or measured mass value is outside the permitted range. Er7 tout Zeroing or tare timeout AS · The zeroing or tare operation could not be completed in time because stability was not achieved. Er8 outr Input value out of range AS · The entered value is outside the permitted range. Er9 Lock Function locked AS · The selected function cannot be used because of the current legal lock. Er10 cal Calibration error AS · The calibration process could not be completed successfully. Er1 Hi Initial mass out of range MAC · The initial mass is outside the permitted range. Er2 nu A/D lower limit exceeded MAC · The A/D measurement value is below the lower limit. Er3 Fu A/D upper limit exceeded MAC · The A/D measurement value has exceeded the upper limit. Er4 ro Mass or temperature adjustment range error MAC · The mass or temperature adjustment value is outside the permitted range. Er5 Ad A/D converter error MAC · An error was detected in the A/D converter system. Er6 to Process timeout MAC · The operation could not be completed in time because stability was not achieved. Er7 ou Entered value out of range MAC · The entered value is outside the permitted range. uLo Battery charge too low WTC 600 · The battery charge is too low. The balance is about to shut down. Err Lo Single piece weight too small / min > max WTC 600 · In piece counting, the single piece weight is too small, or in +/- checkweighing the Min threshold is greater than Max. Err Hi Value entered exceeds capacity WTC 600 · The single piece, Max threshold, or reference mass entered is greater than the maximum capacity. uLo Battery charge too low WLC · The battery charge is too low. The balance is about to shut down. Err Lo Single piece weight too small / min > max WLC · In piece counting, the single piece weight is too small, or in +/- checkweighing the Min threshold is greater than Max. Err Hi Value entered exceeds capacity WLC · The single piece, Max threshold, or reference mass entered is greater than the maximum capacity. -Err2- Outside zeroing range PS R2 · Err2 indicates that the value to be zeroed is outside the allowed zeroing range. -Err3- Outside tare range PS R2 · Err3 indicates that the value to be tared is outside the allowed tare range. -Err8- Tare / zeroing timeout PS R2 · Err8 indicates that the taring or zeroing operation could not be completed within the allowed time. -NULL- Zero value from converter PS R2 · NULL indicates that the balance is receiving a zero value from its measuring transducer. -FULL- Measuring range exceeded PS R2 · FULL indicates that the load on the weighing pan exceeds the balance's measuring range. -LH- Initial mass error PS R2 · LH indicates that the initial mass measured by the balance at startup is not within the expected range. -Err2- Outside zeroing range AS R2 · Err2 indicates that the value to be zeroed is outside the allowed zeroing range. -Err3- Outside tare range AS R2 · Err3 indicates that the value to be tared is outside the allowed tare range. -Err8- Tare / zeroing timeout AS R2 · Err8 indicates that the taring or zeroing operation could not be completed within the allowed time. -NULL- Zero value from converter AS R2 · NULL indicates that the balance is receiving a zero value from its measuring transducer. -FULL- Measuring range exceeded AS R2 · FULL indicates that the load on the weighing pan exceeds the balance's measuring range. -LH- Initial mass error AS R2 · LH indicates that the initial mass measured by the balance at startup is not within the expected range. -Err2- Outside zeroing range C315 scales · Err2 indicates that the value to be zeroed is outside the allowed zeroing range. -Err3- Outside tare range C315 scales · Err3 indicates that the value to be tared is outside the allowed tare range. -Err8- Tare / zeroing timeout C315 scales · Err8 indicates that a tare, zeroing, initial mass determination or adjustment operation timed out. -null- Zero value from converter C315 scales · NULL indicates that the balance is receiving a zero value from its measuring transducer. -FULL- Measuring range exceeded C315 scales · FULL indicates that the load on the platform scale exceeds the weighing range. -LH- Initial mass error C315 scales · LH indicates that the initial mass measured by the balance at startup is not within the expected range. -Err4- Adjustment or ınitial mass out of range C315 scales · Err4 indicates that the adjustment weight or the initial mass is outside the permitted range. -Err5- Battery fault C315 scales · Err5 indicates that the scale has detected a battery fault and the battery is damaged. -Hi- Total display range exceeded C315 scales · Hi indicates that in Totalizing mode the total mass exceeds the range the display can show. -Err Lo- Unit weight too light / min > max C315 scales · Err Lo indicates that the unit weight set for parts counting is too small, or that the Min threshold was entered higher than Max in +/- check mode. -Err Hi- Entered value exceeds capacity C315 scales · Err Hi indicates that the entered unit weight, Max threshold or reference mass is greater than the scale's maximum capacity. Max weighing threshold exceeded / Unload the weighing pan Maximum weighing limit exceeded PS X2 · This message indicates that the load exceeds the balance's maximum weighing limit and the pan must be emptied. Min weighing threshold exceeded / Install weighing pan Below minimum weighing limit PS X2 · This message indicates that the measured value has dropped below the lower limit and the pan must be installed. Zeroing out of range / Press tarring button or restart the balance Zeroing out of range PS X2 · This message indicates that the value to be zeroed is outside the permitted zeroing range. Display capacity out of range / Unload the weighing pan Display capacity exceeded PS X2 · This message indicates that the result exceeds the range the display can show and the pan must be emptied. Tarring out of range / Press zeroing button or restart the balance Tare out of range PS X2 · This message indicates that the value to be tared is outside the permitted tare range. Start mass out of range / Install weighing pan Initial mass out of range PS X2 · This message indicates that the initial mass measured at startup is not within the expected range and the pan must be installed. Max weighing threshold exceeded / Unload the weighing pan Maximum weighing limit exceeded AS X2 · This message indicates that the load exceeds the balance's maximum weighing limit and the pan must be emptied. Min weighing threshold exceeded / Install weighing pan Below minimum weighing limit AS X2 · This message indicates that the measured value has dropped below the lower limit and the pan must be installed. Zeroing out of range / Press tarring button or restart the balance Zeroing out of range AS X2 · This message indicates that the value to be zeroed is outside the permitted zeroing range. Display capacity out of range / Unload the weighing pan Display capacity exceeded AS X2 · This message indicates that the result exceeds the range the display can show and the pan must be emptied. Tarring out of range / Press zeroing button or restart the balance Tare out of range AS X2 · This message indicates that the value to be tared is outside the permitted tare range. Start mass out of range / Install weighing pan Initial mass out of range AS X2 · This message indicates that the initial mass measured at startup is not within the expected range and the pan must be installed. Max weighing threshold exceeded / Unload the weighing pan Maximum weighing limit exceeded C32 scales · This message indicates that the load exceeds the balance's maximum weighing limit and the pan must be emptied. Min weighing threshold exceeded / Install weighing pan Below minimum weighing limit C32 scales · This message indicates that the measured value has dropped below the lower limit and the pan must be installed. Zeroing out of range / Press tarring button or restart the balance Zeroing out of range C32 scales · This message indicates that the value to be zeroed is outside the permitted zeroing range. Display capacity out of range / Unload the weighing pan Display capacity exceeded C32 scales · This message indicates that the result exceeds the range the display can show and the pan must be emptied. Tarring out of range / Press zeroing button or restart the balance Tare out of range C32 scales · This message indicates that the value to be tared is outside the permitted tare range. Start mass out of range / Install weighing pan Initial mass out of range C32 scales · This message indicates that the initial mass measured at startup is not within the expected range and the pan must be installed. Zeroing/tarring time out of range / Weighing indication unstable Zeroing / tare timeout C32 scales · This message indicates that the zeroing or taring operation could not be completed in time because the indication was unstable. Max weighing threshold exceeded / Unload the weighing pan Max weighing threshold exceeded MA 5Y · The sample on the pan exceeds the capacity of the moisture analyzer. Display capacity out of range / Unload the weighing pan Display capacity out of range MA 5Y · The result exceeds the range the display can show. Min weighing threshold exceeded / Install weighing pan Min weighing threshold exceeded MA 5Y · The reading has fallen below the lower limit and the pan must be installed. Zeroing out of range / Press tarring button or restart the balance Zeroing out of range MA 5Y · The value to be zeroed is outside the permitted zeroing range. Start mass out of range / Install weighing pan Start mass out of range MA 5Y · The start mass measured at power-up is not in the expected range. Zeroing/tarring time out of range / Weighing indication unstable Zeroing/tarring time out of range MA 5Y · Zeroing or taring was not completed in time because the reading was unstable. Tarring out of range / Press zeroing button or restart the balance Tarring out of range MA 5Y · The value to be tared is outside the permitted tare range. -no level- Not levelled MA 5Y · The moisture analyzer is not level. -Err 100- Weighing module restart MA 5Y · The weighing module of the analyzer is restarting.