Minebea ıntec scale error codes

3 series · 0 error codes

Minebea Intec is the German manufacturer that continues Sartorius's industrial weighing division. It makes weighing indicators, complete benchtop/floor scales and tank-silo weighing electronics. This guide covers the ERR/INF error codes from the manuals for the Combics 3 indicator, Signum 1/2/3 complete scales and X3 PR 5410 process indicator.

ERR 101 - 104 Key stuck Combics 3 · ERR 101 - 104 indicates that a key is stuck or a key was pressed while the device was powering up. ERR 320 Program memory failure Combics 3 · ERR 320 indicates that the operating program memory is faulty. ERR 335 Incompatible approved platform Combics 3 · ERR 335 indicates that the connected approved weighing platform is not compatible with the terminal. ERR 340 Operating parameter (EEPROM) error Combics 3 · ERR 340 indicates that the operating parameters in the EEPROM are faulty. ERR 341 RAM data lost Combics 3 · ERR 341 indicates that the data in RAM has been lost. ERR 343 Alibi memory transaction number loss Combics 3 · ERR 343 indicates data loss in the area of the external alibi memory where transaction numbers are stored. INF 01 Data output format incompatible Combics 3 · INF 01 indicates that the data output is not compatible with the set output format. INF 02 Calibration condition not met Combics 3 · INF 02 indicates that a required condition was not met at the start of calibration/adjustment. INF 03 Calibration not completed in time Combics 3 · INF 03 indicates that the calibration could not be completed within the set time. INF 06 Internal adjustment weight missing/faulty Combics 3 · INF 06 indicates that the internal adjustment weight is missing or faulty. INF 07 Function not allowed on approved device Combics 3 · INF 07 indicates that the requested function is not permitted on a scale in legal (approved) use. INF 08 Load too large for zeroing Combics 3 · INF 08 indicates that the load on the scale is too heavy for zeroing. INF 09 No tare below gross zero Combics 3 · INF 09 indicates that tare cannot be taken while the gross weight is below zero. INF 10 Tare memory full Combics 3 · INF 10 indicates that the tare key is locked while the tare memory contains data. INF 22 Reference value could not be saved Combics 3 · INF 22 indicates that the reference value could not be saved. INF 23 Application could not be started Combics 3 · INF 23 indicates that an error occurred while starting an application program. INF 29 Minimum load not reached Combics 3 · INF 29 indicates that the minimum load defined for the application has not been reached. INF 71 Invalid value Combics 3 · INF 71 indicates that the current weight value or the entry could not be saved. INF 72 Maximum count reached Combics 3 · INF 72 indicates that the current weight value could not be saved, for example because the transaction counter has reached its maximum. INF 73 Data not found / cannot be read Combics 3 · INF 73 indicates that the data stored in memory cannot be found or read. INF 74 Function disabled Combics 3 · INF 74 indicates that the requested function is disabled (e.g. the menu is locked). INF 98 Weighing platform not connected Combics 3 · INF 98 indicates that no weighing platform is connected to the terminal. INF 99 Weighing platform not connected Combics 3 · INF 99 indicates that no weighing platform is connected to the terminal. NO WP Weighing platform not connected Combics 3 · NO WP indicates that no weighing platform is connected to the terminal. Err 101 Key stuck Signum 1/2/3 · Err 101 indicates that a key is stuck or a key was pressed while the device was powering up. Err 320 Program memory failure Signum 1/2/3 · Err 320 indicates that the operating program memory is faulty. Err 335 Incompatible approved platform Signum 1/2/3 · Err 335 indicates that the connected approved weighing platform is not compatible with the terminal. Err 340 Operating parameter (EEPROM) error Signum 1/2/3 · Err 340 indicates that the operating parameters in the EEPROM are faulty. Err 341 RAM data lost Signum 1/2/3 · Err 341 indicates that the data in RAM has been lost. Err 343 Alibi memory transaction number loss Signum 1/2/3 · Err 343 indicates data loss in the area of the external alibi memory where transaction numbers are stored. Inf 01 Data output format incompatible Signum 1/2/3 · Inf 01 indicates that the data output is not compatible with the set output format. Inf 02 Calibration condition not met Signum 1/2/3 · Inf 02 indicates that a required condition was not met at the start of calibration/adjustment. Inf 03 Calibration not completed in time Signum 1/2/3 · Inf 03 indicates that the calibration could not be completed within the set time. Inf 06 Internal adjustment weight faulty Signum 1/2/3 · Inf 06 indicates that the internal calibration weight is faulty (SIWS models only). Inf 07 Function not allowed on approved device Signum 1/2/3 · Inf 07 indicates that the requested function is not permitted on a scale in legal (approved) use. Inf 08 Load too large for zeroing Signum 1/2/3 · Inf 08 indicates that the load on the scale is too heavy for zeroing. Inf 09 No tare below gross zero Signum 1/2/3 · Inf 09 indicates that tare cannot be taken while the gross weight is below zero. Inf 10 Tare memory full Signum 1/2/3 · Inf 10 indicates that the tare key is locked while the tare memory contains data. Inf 22 Reference value could not be saved Signum 1/2/3 · Inf 22 indicates that the reference value could not be saved. Inf 23 Application could not be started Signum 1/2/3 · Inf 23 indicates that an error occurred while starting an application program. Inf 29 Minimum load not reached Signum 1/2/3 · Inf 29 indicates that the minimum load defined for the application has not been reached. Inf 71 Invalid value Signum 1/2/3 · Inf 71 indicates that the current weight value or the entry could not be saved. Inf 73 Data not found / cannot be read Signum 1/2/3 · Inf 73 indicates that the data stored in memory cannot be found or read. Inf 74 Function disabled Signum 1/2/3 · Inf 74 indicates that the requested function is disabled (e.g. the menu is locked). Inf 98 Weighing platform not connected Signum 1/2/3 · Inf 98 indicates that no weighing platform is connected. Inf 99 Weighing platform not connected Signum 1/2/3 · Inf 99 indicates that no weighing platform is connected. NO WP Weighing platform not connected Signum 1/2/3 · NO WP indicates that no weighing platform is connected. ! (yanıp söner) Battery fault or clock changed Signum 1/2/3 · A flashing ! symbol indicates that the internal battery is faulty or the clock has changed. Error 1 Internal arithmetic overflow X3 PR 5410 · Error 1 (Arith. error) indicates an internal arithmetic overflow in the measuring circuit. Error 2 Overload X3 PR 5410 · Error 2 (Overload) indicates that the measuring signal exceeds the maximum capacity plus the permitted number of divisions. Error 3 External measuring device error X3 PR 5410 · Error 3 (Ext. meas. device error) indicates that the measuring input is open or no value can be read from the scale. Error 4 Value cannot be displayed X3 PR 5410 · Error 4 (Value exceeds display) indicates that the weight value cannot be shown on the display. Error 6 No sense voltage X3 PR 5410 · Error 6 (No sense voltage) indicates that the load cell sense voltage is not detected. Error 7 Negative input signal X3 PR 5410 · Error 7 (Negative input) indicates that the measuring signal is negative. Error 8 Incompatible units X3 PR 5410 · Error 8 (Incompatible units) indicates that the units are incompatible in digital load cells. Error 9 No values from scale X3 PR 5410 · Error 9 (No values from scale) indicates that no weight value can be read from the scale/load cells. Error 11 No weight data X3 PR 5410 · Error 11 (No weight data) indicates that no weight is displayed from the selected weighing point. Error 12 Scale not ready X3 PR 5410 · Error 12 (Scale not ready) indicates that the scale is not ready for weighing. Error 13 Wrong configuration X3 PR 5410 · Error 13 (Wrong configuration) indicates that the number of load cells found does not match the configuration. Error 15 Wrong serial number X3 PR 5410 · Error 15 (Wrong serial number) indicates that the scale's serial number does not match the number set in the device. Err 23 Cannot boot X3 PR 5410 · Err 23 indicates that the device cannot boot. Err 32 IP address in use X3 PR 5410 · Err 32 indicates that the set IP address is already in use on the network. Err 34 No ethernet connection X3 PR 5410 · Err 34 indicates that no Ethernet cable connection (LINK) is found. Err 41 Major system error X3 PR 5410 · Err 41 indicates that a major system error has occurred in the device. Err 44 Cannot write to EAROM X3 PR 5410 · Err 44 indicates that data could not be saved to the EAROM memory. Err 61 CAL switch off X3 PR 5410 · Err 61 indicates that the calibration (CAL) switch is off. Err 68 No mechanical stability X3 PR 5410 · Err 68 indicates that mechanical stability (steadiness) cannot be achieved on the scale. Err 72 Weighing point not ready X3 PR 5410 · Err 72 indicates that the internal weighing point is not ready because of warm-up, auto-tare, or power-up under load. Err 73 Dead load too low X3 PR 5410 · Err 73 indicates that the dead load value is below -0.1 mV/V. Err 75 Weight below dead load X3 PR 5410 · Err 75 indicates that the current weight is below the dead load. Err 78 Capacity smaller than calibration weight X3 PR 5410 · Err 78 indicates that the maximum capacity is set lower than the calibration weight. Err 80 Dead load + capacity too high X3 PR 5410 · Err 80 indicates that the sum of the dead load and the maximum capacity is too high. Err 95 Digital load cell communication error X3 PR 5410 · Err 95 indicates a communication error with Minebea Intec digital load cells.