Dini argeo scale error codes

4 series · 0 error codes

Italian company Dini Argeo makes DFW indicators used on platform and pallet scales, 3590E/CPWE indicators common in weighbridge and batching applications, and DGT series panel-mount indicators and transmitters. This guide covers the error and warning messages from the manuals for the DFW, 3590E, DGT/DGTP/DGTQ and DGT4 series.

BUSY Printer busy DFW · A new printout cannot be made because the previous print job is not finished. UNSTAB Weight unstable DFW · Printing or taring cannot be done because the weight value is not stable. low Weight insufficient or negative DFW · The net or gross weight is negative or below the minimum value required for printing. un.over Underload or overload DFW · Printing cannot be done because the weight is below or above the measuring range. no.0.unS Pan not unloaded DFW · A new printout was blocked because the scale was not unloaded after the last printout. err.mot Weight unstable while taking sample DFW · The operation was not performed because the weight was not steady while taking the sample for piece counting. Error Sample weight insufficient DFW · The sample weight is insufficient for accurate sampling in piece counting. LoW.bAtt Low battery DFW · The internal battery is about to run out. The device will shut itself off shortly. Zero Cannot zero at startup DFW · The scale cannot automatically zero the weight at startup, so it keeps showing the Zero message. C.Er. – 8.03 Multi-range calibration error 3590E · In multi-range calibration, the ranges were not entered in ascending order. C.Er. – 36 Negative signal in calibration 3590E · Internal negative points were calculated during calibration. Er – 37 / No.Cal Calibration point insufficient 3590E · An internal point below the minimum value was calculated in calibration. Err. – 38 Invalid calibration range 3590E · The device is not calibrated because the calibration ranges are invalid. Er – 39 No calibration 3590E · The number of calibration ranges is invalid. The device is in an uncalibrated state. Er – 40 Range 1 value is zero 3590E · The "range 1" parameter in calibration is stored as 0. Er – 41 Division 1 value is zero 3590E · The "diV 1" division parameter in calibration is stored as 0. Err. – 72 Corner-correction weight too low 3590E · The corner/cell equalization coefficient adjustment could not be made because the test weight is too light. Err. – 85 Equalization when not calibrated 3590E · The equalization coefficient cannot be adjusted because the device is not calibrated. ErPnt Zero signal in calibration 3590E · An empty (zero) value was read from the converter when taking the calibration point. hW-Err Hardware mismatch 3590E · The software is not compatible with the installed hardware, or a required hardware component is missing. Error General setup error 3590E · An invalid value, or a connection/setup error, occurred in SET-UP or calibration. - OUT CAPACITY ! - / OVERLOAD Overload 3590E · The weight exceeds the maximum capacity by more than 9 divisions. - OUT CAPACITY ! - / UNDERLOAD Underload 3590E · The weight has dropped below the permitted limit of gross zero. NON VALID OR UNSTABLE WEIGHT Invalid or unstable weight 3590E · Printing/totaling cannot be done because the weight is zero, negative, unstable, or outside the totaling range. NO ZERO CROSS OR INSTABILITY No pass through zero 3590E · A new print/totaling cannot be done until the weight passes through net zero or becomes unstable. PRINTER ERROR: CHECK THE CTS! Printer error 3590E · An error occurred during printing. Totaling could not be done or the printout was not completed. AL.Err Alibi memory error DGT / DGTP / DGTQ · Alibi memory is selected but the card is not detected or cannot be communicated with. buSY Printer busy DGT / DGTP / DGTQ · The printer port is busy, or the indicator is waiting to send output to the PC. unStAb Printing with unstable weight DGT / DGTP / DGTQ · Printing was attempted before the weight stabilized. un.oVEr Printing out of range DGT / DGTP / DGTQ · Printing was attempted while the weight was in an underload or overload condition. ------ Overload / underload DGT / DGTP / DGTQ · Dashes on the display: the weight is above or below the measuring range. GroS.Er Gross weight not positive DGT / DGTP / DGTQ · Printing was attempted while the gross weight was zero or negative. nEt.Err Net weight not positive DGT / DGTP / DGTQ · Printing was attempted while the net weight was zero or negative. LoW Below minimum weight DGT / DGTP / DGTQ · The net weight is below the minimum value required for printing or totaling. no.0.unS No pass through zero DGT / DGTP / DGTQ · A new printout was requested before the weight passed through net zero or became unstable. ConV. Printing in unit conversion DGT / DGTP / DGTQ · Printing was attempted while an approved device was in unit conversion mode. no in Duplicate entry weighing DGT / DGTP / DGTQ · An attempt was made to take the entry weight a second time in entry/exit mode. no out Duplicate exit weighing DGT / DGTP / DGTQ · An attempt was made to take the exit weight a second time in entry/exit mode. Er.Mot Unstable weight in counting DGT / DGTP / DGTQ · The sample was not taken because the weight was unstable in piece counting. Error Insufficient sample quantity DGT / DGTP / DGTQ · The sample was not taken because a higher reference piece count must be used in piece counting. Err.CLK Clock board communication error DGT / DGTP / DGTQ · The indicator cannot communicate with the date/time unit. PrEC. Number of calibration points not confirmed DGT / DGTP / DGTQ · An attempt was made to take a calibration point without confirming the number of points. ErPnt Zero signal in calibration DGT / DGTP / DGTQ · An empty value was read from the converter when taking the calibration point. Er- 11 Calibration weight too small DGT / DGTP / DGTQ · A sample weight that is too small was used in calibration. Er- 12 Calibration point equal to zero DGT / DGTP / DGTQ · The calibration point taken (tP1/tP2/tP3) is the same as the zero point (tP0). Er-37 Balance must be calibrated DGT / DGTP / DGTQ · The balance is not calibrated. According to the technical manual, calibration is required. Er-39 Calibration required DGT / DGTP / DGTQ · The balance is not calibrated and cannot weigh. preC Number of points not confirmed DGT4 · An attempt was made to take a calibration point without confirming the number of points (n tp). er.mot Unstable weight in calibration DGT4 · The weight was unstable when the calibration point was taken. erpnt Zero signal in calibration DGT4 · An empty value was read from the converter when taking the calibration point. err.x.1 Channel capacity/calibration error DGT4 · The capacity of channel X is not set, or there is an error in the calibration parameters. er 11 Calibration weight too low DGT4 · A sample weight that is too low was used in calibration. er 12 Calibration point equal to zero DGT4 · The calibration point taken (tp 1/tp 2/tp 3) is the same as the zero point (tp0). er 37 Balance must be calibrated DGT4 · The balance/channel is not calibrated. er 39 Calibration required DGT4 · The balance/channel is not calibrated. The weighing value is not valid. C.er. -36 Negative signal in calibration DGT4 · Negative internal points were calculated during calibration. C.er. -37 Calibration point insufficient DGT4 · Internal points below the minimum value were calculated in calibration. hw.err Hardware mismatch DGT4 · The software is not compatible with the installed hardware. al.err Alibi memory card missing DGT4 · Alibi memory is enabled but no card was detected at startup. busy Printer port busy DGT4 · Printing is in progress, or the transmitter is waiting to send output to the PC. unstab Printing with unstable weight DGT4 · Printing was attempted while the weight was unstable. un.over Printing out of range DGT4 · Printing was attempted while the weight was in an underload or overload condition. ------ Overload / underload DGT4 · Dashes on the display: the weight is above or below the measuring range. Gros.er Gross weight not positive DGT4 · Printing was attempted while the gross weight was zero or negative. low Below minimum weight DGT4 · The net weight is below the minimum value required for printing. no.0.uns No pass through zero DGT4 · A new printout was requested before the weight passed through net zero or became unstable. Conv Printing in unit conversion DGT4 · Printing was attempted while the transmitter was in unit conversion mode. err.CLk Clock board communication error DGT4 · The transmitter cannot communicate with the clock board.