Code on display ------ Dini Argeo DGT4

Overload / underload

It is displayed as overload when capacity is exceeded by 9 divisions, and as underload when the reading falls below -100 divisions on an approved device or below -capacity -9 divisions on a non-approved one.

Check it yourself first. If it continues, it needs service.

What should you do?

Try the steps in order.

  1. Remove the excess load.
  2. Check that the weighing structure is not touching anything.
  3. Zero when empty.
  • Do not load the system above capacity.

Possible causes

  • Load above capacity
  • Load cell mechanically jammed
  • Zero drift

Do you need service?

If the dashes persist on the empty system, service is required for a load cell or cable fault.

Models showing this code: DGT4, DGT4AN, DGT4PB, DGT4PRONET, DGT4ETHIP, DGT4MODTCP, DGT4ETHCAT, DGT4DEVNET, DGT4CANOP

Source: Dini Argeo official user manual