Underload
This occurs when the reading falls below gross zero by 100 divisions on an approved device, or below capacity + 9 divisions on a non-approved device. It usually means the platform was lifted or the zero has drifted.
Check it yourself first. If it continues, it needs service.
What should you do?
Try the steps in order.
- Check that the platform is seated properly and is not jammed.
- Zero with the ZERO key on an empty platform.
- Switch the device off and on again.
Possible causes
- Platform or pan dislodged
- Removal of a container that was zeroed with tare
- Zero point drift
Do you need service?
If the warning persists on an empty, properly seated platform, the load cell or cable must be checked by service.
Models showing this code: 3590EKR, 3590EXP, 3590EXT, 3590EDX, CPWE, CPWET
Source: Dini Argeo official user manual
Legal notice
The error code explanations and checks on this page are based on manufacturer manuals and are provided for general information only; they do not replace technical service, diagnosis or warranty. The meaning of a code may vary by model, firmware version and configuration.
The decision to carry out any suggested step, and its consequences, rest with the user. Terazibul cannot be held liable for device damage, weighing errors, data loss, commercial loss or any other direct or indirect damage arising from the use of this information.
On legal-for-trade (verified) scales, adjustment and calibration must only be performed by a qualified technical service in line with legal metrology rules. Disconnect power before opening the device and contact a service provider if in doubt. Brand and model names belong to their respective owners and are used only to identify the device.