Minebea Intec

X3 PR 5410 error codes

25 error codes

Review the 25 error and warning messages from the Minebea Intec X3 PR 5410 manufacturer manual, with meanings and fix steps. Device type: process weighing indicator.

Covered models: PR 5410, PR5410/00, PR5410/01, PR5410/03, X3

Error 1 Internal arithmetic overflow Error 1 (Arith. error) indicates an internal arithmetic overflow in the measuring circuit. Error 2 Overload Error 2 (Overload) indicates that the measuring signal exceeds the maximum capacity plus the permitted numb… Error 3 External measuring device error Error 3 (Ext. meas. device error) indicates that the measuring input is open or no value can be read from t… Error 4 Value cannot be displayed Error 4 (Value exceeds display) indicates that the weight value cannot be shown on the display. Error 6 No sense voltage Error 6 (No sense voltage) indicates that the load cell sense voltage is not detected. Error 7 Negative input signal Error 7 (Negative input) indicates that the measuring signal is negative. Error 8 Incompatible units Error 8 (Incompatible units) indicates that the units are incompatible in digital load cells. Error 9 No values from scale Error 9 (No values from scale) indicates that no weight value can be read from the scale/load cells. Error 11 No weight data Error 11 (No weight data) indicates that no weight is displayed from the selected weighing point. Error 12 Scale not ready Error 12 (Scale not ready) indicates that the scale is not ready for weighing. Error 13 Wrong configuration Error 13 (Wrong configuration) indicates that the number of load cells found does not match the configuration. Error 15 Wrong serial number Error 15 (Wrong serial number) indicates that the scale's serial number does not match the number set in th… Err 23 Cannot boot Err 23 indicates that the device cannot boot. Err 32 IP address in use Err 32 indicates that the set IP address is already in use on the network. Err 34 No ethernet connection Err 34 indicates that no Ethernet cable connection (LINK) is found. Err 41 Major system error Err 41 indicates that a major system error has occurred in the device. Err 44 Cannot write to EAROM Err 44 indicates that data could not be saved to the EAROM memory. Err 61 CAL switch off Err 61 indicates that the calibration (CAL) switch is off. Err 68 No mechanical stability Err 68 indicates that mechanical stability (steadiness) cannot be achieved on the scale. Err 72 Weighing point not ready Err 72 indicates that the internal weighing point is not ready because of warm-up, auto-tare, or power-up u… Err 73 Dead load too low Err 73 indicates that the dead load value is below -0.1 mV/V. Err 75 Weight below dead load Err 75 indicates that the current weight is below the dead load. Err 78 Capacity smaller than calibration weight Err 78 indicates that the maximum capacity is set lower than the calibration weight. Err 80 Dead load + capacity too high Err 80 indicates that the sum of the dead load and the maximum capacity is too high. Err 95 Digital load cell communication error Err 95 indicates a communication error with Minebea Intec digital load cells.