CAS scale error codes

7 series · 48 error codes

On CAS weighing devices, error codes vary by series. Look up the codes for the CPS pallet scale and CPS-PLUS series separately, without mixing them up.

Err 01 Initial stability error CPS · The device cannot produce a stable weight value at startup. Err 02 Load cell or A/D connection error CPS · An error was detected in the load cell connection or the A/D conversion system. Err 06 Printer connection error CPS · The scale cannot communicate with the connected printer. Err 08 Zero or tare operation while unstable CPS · Err 08 indicates that the zero, tare or start key was pressed on a CAS CPS device while the weight was unstable. Err 09 Out of zero range CPS · The current weight is outside the range permitted for zeroing. Err 10 Tare capacity exceeded CPS · The entered tare weight is greater than the maximum capacity of the scale. Err 01 Initial stability error CPS-PLUS · The device cannot produce a stable weight value at startup. Err 02 Load cell or A/D connection error CPS-PLUS · An error was detected in the load cell connection or the A/D conversion system. Err 06 Printer connection error CPS-PLUS · The scale cannot communicate with the connected printer. Err 08 Zero or tare operation while unstable CPS-PLUS · Err 08 indicates that the zero, tare or start key was pressed on a CAS CPS-PLUS device while the weight was unstable. Err 09 Out of zero range CPS-PLUS · The current weight is outside the range permitted for zeroing. Err 10 Tare capacity exceeded CPS-PLUS · The entered tare weight is greater than the maximum capacity of the scale. Err 05 Key entry error CPS-PLUS · A key has been held down for a long time or an abnormality was detected in the key circuit. Err 12 Printer function mismatch CPS-PLUS · The selected printer type does not support the requested total printout. Err 13 Zero adjustment value out of range CPS-PLUS · Err 13 indicates that the zero point value is out of range during weight adjustment on a CAS CPS-PLUS device. Err 15 Item code range error CPS-PLUS · The entered product/item code exceeds the permitted number range. Err 82 A/D system error CPS-PLUS · An abnormality was detected in the analog/digital measurement system. Over Overload CPS-PLUS · The load on the platform exceeds the maximum permitted capacity. Err 20 Resolution exceeds 1/10,000 limit CPS-PLUS · Err 20 indicates that the resolution exceeds the 1/10,000 limit during weight adjustment on the CAS CPS-PLUS. Err 21 Resolution exceeds 1/30,000 limit CPS-PLUS · Err 21 indicates that the resolution exceeds the 1/30,000 limit during weight adjustment on the CAS CPS-PLUS. Err 22 Calibration weight less than 10% of capacity CPS-PLUS · Err 22 indicates that the span adjustment weight entered is less than 10% of capacity on the CAS CPS-PLUS. Err 23 Calibration weight exceeds capacity CPS-PLUS · Err 23 indicates that the span adjustment weight entered is more than 100% of capacity on the CAS CPS-PLUS. Err 24 Span too low CPS-PLUS · Err 24 indicates that the load cell output (span) is too low during weight adjustment on the CAS CPS-PLUS. Err 25 Span too high CPS-PLUS · Err 25 indicates that the load cell output (span) is too high during weight adjustment on the CAS CPS-PLUS. Err 26 Zero point too high CPS-PLUS · Err 26 indicates that the zero point is too high during weight adjustment on the CAS CPS-PLUS. Err 27 Zero point too low CPS-PLUS · Err 27 indicates that the zero point is too low during weight adjustment on the CAS CPS-PLUS. Err 28 Weight unstable (during adjustment) CPS-PLUS · Err 28 indicates that the weight is fluctuating during weight adjustment on the CAS CPS-PLUS. ERR-Set Serial port setting mismatch CPS-PLUS · ERR-Set indicates that printing is not possible because of the serial port settings on the CAS CPS-PLUS. E1 Calibration data lost XE · The calibration data in the scale memory has been lost. E2 Initial zero out of range XE · At power on the initial zero is outside the allowed range. E3 No weighing signal XE · The scale receives no signal from the load cell. E4 Lower limit greater than upper limit XE · In check weighing the low limit has been set higher than the high limit. ADM NOT IN Weighing module not responding CL3000 · The scale cannot communicate with the A/D weighing module. AD-Conv A/D conversion error CL3000 · The weighing signal cannot be converted to a digital value. .Chk MEM Err Memory check failed at startup CL3000 · The scale could not complete the memory check during startup. .Key Error Key pressed at startup CL3000 · At startup the scale detected a pressed key or a keypad problem. Zero RNG Err Zero range error CL3000 · At startup the zero point is outside the allowed range. UNSTABLE Weight unstable CL3000 · The scale or the weight on it cannot settle. Overload! Maximum weight exceeded CL3000 · The weight on the platter is above the maximum capacity. Tare Over Tare too high CL3000 · The tare value exceeds the maximum tare allowed by the scale. Already Tare Tare already set CL3000 · A new tare was attempted while a tare is already set. No Tare No tare to clear CL3000 · Tare clearing was attempted while no tare is set. Open TPH Printer head open CL3000 · Printing was attempted while the printer head is open. Paper End Paper end CL3000 · The label or ticket roll in the printer has run out. Press FEED Press FEED CL3000 · The FEED key must be pressed before printing after a paper change. PEEL - OFF Remove printed label CL3000 · The scale is waiting because a printed label has not been removed. Gap Chk Err Wrong label paper CL3000 · The loaded paper does not match the paper type set for the printer. PRINT ERROR Print error CL3000 · An error occurred during printer output. Check weight Check weight CL3000 · The weight is zero when a label print is requested. Check price Check price CL3000 · Print was pressed while the total amount is zero. Check Min WT Below minimum weight CL3000 · The item weight is below the minimum weight of the scale. Remov weight Remove weight CL3000 · There is weight on the platter during a by-piece or by-count sale. Memory full Memory full CL3000 · The sales data buffer is full and no new sale can be made. Data Full !! Data table full CL3000 · The memory for the data table being programmed is full. Net - Err Network error CL3000 · The scale cannot communicate over the network. NO MASTER No master scale CL3000 · The connection to the master scale on the network has been lost. BACKUP FAIL! Backup failed CL3000 · Data could not be backed up to USB memory. Err 0 Weight unstable ER Jr · The scale cannot read a stable weight. Err 1 Zero point shifted ER Jr · The zero point has shifted from the last span calibration. Err 3 Overload ER Jr · The weight on the platter exceeds the scale capacity. Err 4 Payment too low ER Jr · In change calculation the payment entered is less than the total. Err 5 Tare already set ER Jr · A tare value is already set on the scale. Err 6 Total price overflow ER Jr · The sale total exceeds what the display can show. Err 8 Euro price overflow ER Jr · The price calculated with the euro rate exceeds the limit. Err 13 Soft key code broken ER Jr · The code of a soft key is lost or corrupted. Err 15 Half or quarter price overflow ER Jr · The 1/2 or 1/4 unit price calculation exceeds the limit. Err 0 Weight unstable PB · The scale cannot read a stable weight. Err 1 Initial zero error PB · At power on the zero point has shifted from the last span calibration. Err 3 Overload PB · The weight on the platform exceeds capacity. Err 9 No weight for counting PB · There is no weight on the platform in counting mode. Err 1 Zero range error SW · At power on the initial zero is outside the allowed range. O-L Overload SW · The weight on the platter exceeds the scale capacity. LObAt Battery low SW · The battery voltage is too low and the scale will switch off.