Dini Argeo

3590E error codes

17 error codes

Review the 17 error and warning messages from the Dini Argeo 3590E manufacturer manual, with meanings and fix steps. Device type: industrial weighing terminal.

Covered models: 3590EKR, 3590EXP, 3590EXT, 3590EDX, CPWE, CPWET

C.Er. – 8.03 Multi-range calibration error In multi-range calibration, the ranges were not entered in ascending order. C.Er. – 36 Negative signal in calibration Internal negative points were calculated during calibration. Er – 37 / No.Cal Calibration point insufficient An internal point below the minimum value was calculated in calibration. Err. – 38 Invalid calibration range The device is not calibrated because the calibration ranges are invalid. Er – 39 No calibration The number of calibration ranges is invalid. The device is in an uncalibrated state. Er – 40 Range 1 value is zero The "range 1" parameter in calibration is stored as 0. Er – 41 Division 1 value is zero The "diV 1" division parameter in calibration is stored as 0. Err. – 72 Corner-correction weight too low The corner/cell equalization coefficient adjustment could not be made because the test weight is too light. Err. – 85 Equalization when not calibrated The equalization coefficient cannot be adjusted because the device is not calibrated. ErPnt Zero signal in calibration An empty (zero) value was read from the converter when taking the calibration point. hW-Err Hardware mismatch The software is not compatible with the installed hardware, or a required hardware component is missing. Error General setup error An invalid value, or a connection/setup error, occurred in SET-UP or calibration. - OUT CAPACITY ! - / OVERLOAD Overload The weight exceeds the maximum capacity by more than 9 divisions. - OUT CAPACITY ! - / UNDERLOAD Underload The weight has dropped below the permitted limit of gross zero. NON VALID OR UNSTABLE WEIGHT Invalid or unstable weight Printing/totaling cannot be done because the weight is zero, negative, unstable, or outside the totaling ra… NO ZERO CROSS OR INSTABILITY No pass through zero A new print/totaling cannot be done until the weight passes through net zero or becomes unstable. PRINTER ERROR: CHECK THE CTS! Printer error An error occurred during printing. Totaling could not be done or the printout was not completed.