Code on display AD LOW Rice Lake 120 Plus

A/D negative range error

The signal reaching the analog-to-digital converter is outside the negative measurement range. The manual recommends checking the scale for binding or damage.

Check it yourself first. If it continues, it needs service.

What should you do?

Try the steps in order.

  1. Check that nothing is rubbing against or pinching the platform.
  2. Check that the platform is seated properly and does not look damaged.
  3. Look for visible crushing or breaks in the cables.
  4. Switch the device off and on again.

Possible causes

  • Platform jammed or pushed upward
  • Load cell cable damaged
  • Load cell damage

Do you need service?

If there is no mechanical binding and the error persists, there is a load cell or cable fault and service is needed.

Models showing this code: 120 Plus, 120+

Source: Rice Lake official user manual