Esit scale error codes

3 series · 0 error codes

Esit Elektronik is an Istanbul-based Turkish manufacturer of weighing systems, producing weighing indicators, load cells, truck scales and filling/batching controllers. The guide covers the error codes of the wireless Smart-2 indicator, the ECI weighing controller with automation features and the ART series indicators.

Error99 ADC not responding Smart-2 · Error99 indicates that the weight measurement circuit (ADC) on the Esit Smart-2 indicator is not responding. Error98 / Error97 ADC serial communication error Smart-2 · Error98 or Error97 indicates faulty serial communication between the Smart-2 main processor and the ADC. Error96 Bluetooth reset error Smart-2 · Error96 indicates that the Bluetooth module on the Smart-2 indicator could not be reset. Error95 Bluetooth sleep mode error Smart-2 · Error95 indicates that the Bluetooth module could not be put into sleep mode. Error94 Bluetooth name change error Smart-2 · Error94 indicates that the Bluetooth device name on the Smart-2 indicator could not be changed. Error93 Wi-fi APID change error Smart-2 · Error93 indicates that the Wi-Fi access point ID (APID) could not be changed. Error92 EEPROM write error Smart-2 · Error92 indicates that settings could not be written to the non-volatile memory (EEPROM) on the Smart-2 indicator. Error91 EEPROM full error Smart-2 · Error91 indicates that the non-volatile memory (EEPROM) is full and new data cannot be written. Error1 Weight upper limit exceeded Smart-2 · Error1 indicates that the weight on the pan exceeds the highest value the indicator allows. Error2 Weight below lower limit Smart-2 · Error2 indicates that the measured weight data has fallen below the lowest allowed value. Error3 Load too large for zeroing Smart-2 · Error3 indicates that the weight on the platform is too large to be zeroed. Error4 ESC or menu key stuck Smart-2 · Error4 indicates that the ESC or Menu key on the Smart-2 indicator remains pressed. Error6 Enter key stuck Smart-2 · Error6 indicates that the Enter key is detected as continuously pressed. Error7 Wi-fi/ble name invalid Smart-2 · Error7 indicates that the name entered for Wi-Fi or Bluetooth is invalid. Error8 Name change while wi-fi is connected Smart-2 · Error8 indicates that a name change was attempted while the Wi-Fi connection is active. Error10 5% of EEPROM life used Smart-2 · Error10 indicates that 5% of the write life of the non-volatile memory (EEPROM) has been used. Error19 Calibration value cannot be zero Smart-2 · Error19 indicates that a value of 0 was entered during calibration and was not accepted. Err50 Calibration switch is off Smart-2 · Err50 indicates that a setting change was attempted while the calibration switch (P2 jumper) is installed/closed. Error51 Mv and v cannot be calibrated Smart-2 · Error51 indicates that the mV and V values could not be calibrated. Error52 Mv and v cannot be zeroed Smart-2 · Error52 indicates that the mV and V values could not be zeroed. Error60 IP address error Smart-2 · Error60 indicates that the device is in STA mode but is not connected to any network. Maximum Load! Maximum load exceeded ECI · Error 1 (Maximum Load!) indicates that the measured value exceeds the capacity + 9e limit. Zero Limit! Zero limit exceeded ECI · Error 3 (Zero Limit!) indicates that the load on the platform exceeds the zeroing limit and cannot be zeroed. LoadCellError Load cell error ECI · Error 5 (LoadCellError) indicates that the load cell may be faulty or there is a connection problem. ADC Data Error! ADC data error ECI · Error 6 (ADC Data Error!) indicates that the indicator's ADC (load cell) module is faulty. Coeff.OutofLimit Calibration coefficient out of limit ECI · Error 10 (Coeff.OutofLimit) indicates that the coefficient calculated from the calibration is outside the limit. Insufficient Load! Calibration load insufficient ECI · Error 11 (Insufficient Load!) indicates that the load used in calibration is insufficient. Memory 1 Error Memory 1 error ECI · Error 22 (Memory 1 Error) indicates that the memory unit cannot be read or written. Memory 2 Error Memory 2 error ECI · Error 24 (Memory 2 Error) indicates that the second memory unit cannot be read or written. PrinterTime.Out Printer timeout ECI · Error 31 (PrinterTime.Out) indicates that the printer connection is faulty or no printer is present. Battery Error Clock battery error ECI · Error 42 (Battery Error) indicates that the date/time information cannot be read. The manual says to replace the battery. No USB USB memory not inserted ECI · Error 50 (No USB) indicates that no USB memory is inserted or detected. No File No file on USB ECI · Error 51 (No File) indicates that the required file is not on the USB memory stick. Corrupted File Corrupted file ECI · Error 52 (Corrupted File) indicates that the file on the USB is corrupted. The manual says to reload the file. Restart! Restart required ECI · Error 53 (Restart!) indicates that the device must be turned off and on again. ShotValueError In-flight value error ECI · Error 61 (ShotValueError) indicates that the in-flight (shot) value was entered larger than the target value. LowTareValue Tare value low ECI · Error 62 (LowTareValue) indicates that the operation could not be started because the tare value is below the Minimum Tare setting. TargetValue.Excess Target value exceeds capacity ECI · Error 64 (TargetValue.Excess) indicates that the target value entered is greater than the capacity. Scale is full Scale full ECI · Error 66 (Scale is full) indicates that filling could not be started because the weight on the platform is greater than the target value. ToleranceError! Tolerance error ECI · Error 71 (ToleranceError!) indicates that more than the set number of errors occurred in one of the silos during dosing. Disc.Tim.Lap Discharge time exceeded ECI · Error 72 (Disc.Tim.Lap) indicates that the weight did not change for the defined time during discharge. ADC ModulError ADC module cannot be read ECI · Error 90 (ADC ModulError) indicates that the ADC module cannot be read. Defective Sensor Temperature sensor fault ECI · Error 91 (Defective Sensor) indicates that the temperature sensor cannot be read. Mobility Operation not possible due to motion ECI · Warning 101 (Mobility) indicates that zeroing or taring could not be done because the weight is not stable. Tare active! Tare active ECI · Warning 102 (Tare active!) indicates that zeroing cannot be done while tare is active. Negative Load Cannot tare under negative load ECI · Warning 103 (Negative Load) indicates that tare cannot be taken at a negative weight. No LC Load cell not connected ART · No LC indicates that the load cell cable is not connected to the ART indicator. Err 01 Overload (capacity) ART · Err 01 indicates that the load on the platform exceeds the maximum allowed weight by 10 divisions. Err 05 Analog input range exceeded ART · Err 05 indicates that the load exceeds the maximum analog input range set during calibration. Err 31 No printer ART · Err 31 indicates that the printer's READY signal timed out during printing. Err-22 Non-volatile memory write error ART · Err-22 indicates that an error occurred while writing to non-volatile memory.