Code on display No LC Esit ART

Load cell not connected

According to the manual, this message appears when the load cell cable is disconnected. The indicator cannot receive a weight signal.

Check it yourself first. If it continues, it needs service.

What should you do?

Try the steps in order.

  1. Connect the load cell cable to the indicator connector.
  2. Check that the connector is fully seated and the cable is not damaged.

Possible causes

  • Load cell cable came out
  • Loose connector
  • Broken cable

Do you need service?

If the message continues with the cable connected, the cable or load cell must be checked by service.

Models showing this code: ART

Source: Esit official user manual