DGT / DGTP / DGTQ error codes

21 error codes

Review the 21 error and warning messages from the Dini Argeo DGT / DGTP / DGTQ manufacturer manual, with meanings and fix steps. Device type: panel-mount weighing indicator.

Covered models: DGTP, DGTPK, DGTQ, DGT60, DGT100, DGT20, DGT1

AL.Err Alibi memory error Alibi memory is selected but the card is not detected or cannot be communicated with. buSY Printer busy The printer port is busy, or the indicator is waiting to send output to the PC. unStAb Printing with unstable weight Printing was attempted before the weight stabilized. un.oVEr Printing out of range Printing was attempted while the weight was in an underload or overload condition. ------ Overload / underload Dashes on the display: the weight is above or below the measuring range. GroS.Er Gross weight not positive Printing was attempted while the gross weight was zero or negative. nEt.Err Net weight not positive Printing was attempted while the net weight was zero or negative. LoW Below minimum weight The net weight is below the minimum value required for printing or totaling. no.0.unS No pass through zero A new printout was requested before the weight passed through net zero or became unstable. ConV. Printing in unit conversion Printing was attempted while an approved device was in unit conversion mode. no in Duplicate entry weighing An attempt was made to take the entry weight a second time in entry/exit mode. no out Duplicate exit weighing An attempt was made to take the exit weight a second time in entry/exit mode. Er.Mot Unstable weight in counting The sample was not taken because the weight was unstable in piece counting. Error Insufficient sample quantity The sample was not taken because a higher reference piece count must be used in piece counting. Err.CLK Clock board communication error The indicator cannot communicate with the date/time unit. PrEC. Number of calibration points not confirmed An attempt was made to take a calibration point without confirming the number of points. ErPnt Zero signal in calibration An empty value was read from the converter when taking the calibration point. Er- 11 Calibration weight too small A sample weight that is too small was used in calibration. Er- 12 Calibration point equal to zero The calibration point taken (tP1/tP2/tP3) is the same as the zero point (tP0). Er-37 Balance must be calibrated The balance is not calibrated. According to the technical manual, calibration is required. Er-39 Calibration required The balance is not calibrated and cannot weigh.