Code on display Err 37 Baykon BX6 / BX6W

Scale not stable

Because the scale/platform is moving, the weight did not stabilize and the requested operation (zeroing, tare, saving, etc.) could not be performed. A value taken under a moving load is not reliable.

Check it yourself first. If it continues, it needs service.

What should you do?

Try the steps in order.

  1. Wait for the movement on the platform to stop and repeat the process.
  2. Make sure no person or object is touching the platform.
  3. If possible, stop nearby sources of vibration (motors, forklifts, etc.).

Possible causes

  • Load or person moving on the platform
  • Vibration or wind
  • Grounding problem

Do you need service?

If the error continues even with the platform still, service must check the grounding connections.

Models showing this code: BX6, BX6W

Source: Baykon official user manual · Open manufacturer document