Weight below lower limit
The weight on the indicator has dropped below the lower limit the device can measure (overload in the negative direction). The weighing result is not reliable in this case, and it should not be recorded or printed.
Check it yourself first. If it continues, it needs service.
What should you do?
Try the steps in order.
- Completely empty the platform.
- Check whether an object is stuck under or beside the platform, and make sure the platform sits freely.
- Turn the device off and on again and see whether the indicator returns to zero.
Possible causes
- Platform lifted or caught on something and pushed up
- Zero point drift
- Load cell or cable fault
Do you need service?
If the Under message continues with the platform empty and free, the load cell or indicator input must be measured by service.
Models showing this code: BX6, BX6W
Source: Baykon official user manual · Open manufacturer document
Legal notice
The error code explanations and checks on this page are based on manufacturer manuals and are provided for general information only; they do not replace technical service, diagnosis or warranty. The meaning of a code may vary by model, firmware version and configuration.
The decision to carry out any suggested step, and its consequences, rest with the user. Terazibul cannot be held liable for device damage, weighing errors, data loss, commercial loss or any other direct or indirect damage arising from the use of this information.
On legal-for-trade (verified) scales, adjustment and calibration must only be performed by a qualified technical service in line with legal metrology rules. Disconnect power before opening the device and contact a service provider if in doubt. Brand and model names belong to their respective owners and are used only to identify the device.