Code on display t¯¯¯¯¯ Laumas TLB

Zeroing not possible

Zeroing works only for weights within the permitted range. For a larger load the command is rejected (error code 3 is returned over the serial protocol).

Check it yourself first. If it continues, it needs service.

What should you do?

Try the steps in order.

  1. Empty the silo/tank or platform completely.
  2. Issue the zero command again.

Possible causes

  • Product or residual material in the system
  • Zero command issued at the wrong time

Do you need service?

If zeroing is still not possible when empty, the zero point must be recalibrated by a technician.

Models showing this code: TLB, TLB485, TLB CANOPEN, TLB DEVICENET, TLB PROFI, TLB PROFINET IO, TLB ETHERNET/IP, TLB MODBUS/TCP, TLB ETHERCAT

Source: Laumas official user manual