5 series · 0 error codes

Taiwan-based Jadever, with production in Xiamen, makes counting, checkweighing, platform and precision benchtop scales as well as weighing indicators. The guide covers the Err/ERR codes of the JWE checkweighing scales, JCE and JCL counting scales, JWL benchtop scales and the JWI-586 indicator used on JPS platforms.

Err2 Initial zero point exceeded JWE · At startup the scale detected that the zero point is outside the permitted limit (+30%, positive direction). Err3 A/D resolution range exceeded JWE · The signal from the load cell is outside the range the A/D converter can measure. Err4 EEPROM checksum error JWE · A checksum error was detected in the EEPROM memory that stores adjustment and calibration data. Err5 Overload JWE · The load on the weighing pan has exceeded the scale's maximum capacity. Err6 Incorrect calibration weight JWE · The weight placed during calibration does not match the expected value. OVEr1 Accumulation capacity exceeded JWE · The number of accumulated weighings or the total value exceeded the display range. OVEr2 Accumulation capacity exceeded JWE · The number of accumulated weighings or the total value exceeded the display range. Err2 Initial zero point exceeded JCE · At startup the scale detected that the zero point is outside the permitted limit (±30%). Err3 A/D resolution range exceeded JCE · The signal from the load cell is outside the range the A/D converter can measure. Err4 EEPROM checksum error JCE · A checksum error was detected in the EEPROM memory that stores adjustment and calibration data. Err5 Overload JCE · The load on the weighing pan has exceeded the scale's maximum capacity. Err7 Accumulation capacity exceeded JCE · The number of accumulated weighings or the total value exceeded the display range. OVER Unit weight cannot be displayed JCE · The unit weight calculated during sampling in piece counting exceeds the display range. Err Outside display range JWI-586 / JPS · The value is above or below the range the indicator can display. Err2 Initial zero point exceeded JWI-586 / JPS · At startup the zero point deviated more than 10% (+) from the stored value. Err3 / -Err3 Outside A/D range JWI-586 / JPS · The load cell signal is above or below the A/D converter's measurement range. Err4 EEPROM checksum error JWI-586 / JPS · A checksum error was detected in the EEPROM memory that stores adjustment and calibration data. Err5 Overload JWI-586 / JPS · The load on the weighing pan has exceeded the scale's maximum capacity. Err8 Operating unit setting error JWI-586 / JPS · The operating unit and the start unit settings are incompatible. Err9 LOW value greater than hi value JWI-586 / JPS · The lower limit entered for checkweighing is greater than or equal to the upper limit. Over Accumulation count exceeded 99 JWI-586 / JPS · The accumulation count exceeded 99 records. ERR0 Zero range exceeded JCL · When the zero key was pressed, the load on the weighing pan was above the zeroing limit (2% of full capacity). ERR1 Model setting error JCL · The capacity and resolution (division) settings form an invalid combination. ERR2 Initial zero point exceeded JCL · At startup the scale detected that the zero point is outside the permitted limit (30% of full capacity). ERR3 A/D resolution range exceeded JCL · The signal from the load cell is outside the range the A/D converter can measure. ERR4 EEPROM checksum error JCL · A checksum error was detected in the EEPROM memory that stores adjustment and calibration data. ERR5 Overload JCL · The load on the weighing pan has exceeded the scale's maximum capacity. ERR6 Display range exceeded JCL · The value to be displayed exceeds the display's digit capacity. ERR8 Lower limit greater than upper limit JCL · The lower limit entered for checkweighing is greater than or equal to the upper limit. ERR9 Tare range exceeded JCL · The tare or preset tare value is outside the permitted range. ERR10 Incorrect calibration weight JCL · The weight placed during calibration does not match the expected value. ERR0 Zero range exceeded JWL · When the zero key was pressed, the load on the weighing pan was above the zeroing limit (2% of full capacity). ERR2 Initial zero point exceeded JWL · At startup the scale detected that the zero point is outside the permitted limit (30% of full capacity). ERR3 A/D resolution range exceeded JWL · The signal from the load cell is outside the range the A/D converter can measure. ERR4 EEPROM checksum error JWL · A checksum error was detected in the EEPROM memory that stores adjustment and calibration data. ERR5 Overload JWL · The load on the weighing pan has exceeded the scale's maximum capacity. ERR6 Display range exceeded JWL · The value to be displayed exceeds the display's digit capacity. ERR7 Accumulation capacity exceeded JWL · The number of accumulated weighings or the total value exceeded the display range. ERR8 Lower limit greater than upper limit JWL · The lower limit entered for checkweighing is greater than or equal to the upper limit. ERR9 Tare range exceeded JWL · The tare or preset tare value is outside the permitted range. ERR10 Incorrect calibration weight JWL · The weight placed during calibration does not match the expected value.