Review the 21 error and warning messages from the Esit Smart-2 manufacturer manual, with meanings and fix steps. Device type: industrial weighing indicator.

Covered models: Smart-2

Error99 ADC not responding Error99 indicates that the weight measurement circuit (ADC) on the Esit Smart-2 indicator is not responding. Error98 / Error97 ADC serial communication error Error98 or Error97 indicates faulty serial communication between the Smart-2 main processor and the ADC. Error96 Bluetooth reset error Error96 indicates that the Bluetooth module on the Smart-2 indicator could not be reset. Error95 Bluetooth sleep mode error Error95 indicates that the Bluetooth module could not be put into sleep mode. Error94 Bluetooth name change error Error94 indicates that the Bluetooth device name on the Smart-2 indicator could not be changed. Error93 Wi-fi APID change error Error93 indicates that the Wi-Fi access point ID (APID) could not be changed. Error92 EEPROM write error Error92 indicates that settings could not be written to the non-volatile memory (EEPROM) on the Smart-2 ind… Error91 EEPROM full error Error91 indicates that the non-volatile memory (EEPROM) is full and new data cannot be written. Error1 Weight upper limit exceeded Error1 indicates that the weight on the pan exceeds the highest value the indicator allows. Error2 Weight below lower limit Error2 indicates that the measured weight data has fallen below the lowest allowed value. Error3 Load too large for zeroing Error3 indicates that the weight on the platform is too large to be zeroed. Error4 ESC or menu key stuck Error4 indicates that the ESC or Menu key on the Smart-2 indicator remains pressed. Error6 Enter key stuck Error6 indicates that the Enter key is detected as continuously pressed. Error7 Wi-fi/ble name invalid Error7 indicates that the name entered for Wi-Fi or Bluetooth is invalid. Error8 Name change while wi-fi is connected Error8 indicates that a name change was attempted while the Wi-Fi connection is active. Error10 5% of EEPROM life used Error10 indicates that 5% of the write life of the non-volatile memory (EEPROM) has been used. Error19 Calibration value cannot be zero Error19 indicates that a value of 0 was entered during calibration and was not accepted. Err50 Calibration switch is off Err50 indicates that a setting change was attempted while the calibration switch (P2 jumper) is installed/c… Error51 Mv and v cannot be calibrated Error51 indicates that the mV and V values could not be calibrated. Error52 Mv and v cannot be zeroed Error52 indicates that the mV and V values could not be zeroed. Error60 IP address error Error60 indicates that the device is in STA mode but is not connected to any network.