Cutoff / setpoint value error
The cutoff (setpoint) values used for filling/control are corrupted or invalid. Incorrect cutoff values can cause relay outputs to operate at the wrong time.
Check it yourself first. If it continues, it needs service.
What should you do?
Try the steps in order.
- Check the cutoff values and upload them again.
- Turn the device off and on again and test the outputs without a load.
- Do not run automatic filling/process outputs until the cutoff values are corrected.
Possible causes
- Cutoff value data corruption
- Entering an invalid cutoff value
Do you need service?
If the error continues after the cutoff values are uploaded again, service must check the memory and output board.
Models showing this code: BX6, BX6W
Source: Baykon official user manual · Open manufacturer document
Legal notice
The error code explanations and checks on this page are based on manufacturer manuals and are provided for general information only; they do not replace technical service, diagnosis or warranty. The meaning of a code may vary by model, firmware version and configuration.
The decision to carry out any suggested step, and its consequences, rest with the user. Terazibul cannot be held liable for device damage, weighing errors, data loss, commercial loss or any other direct or indirect damage arising from the use of this information.
On legal-for-trade (verified) scales, adjustment and calibration must only be performed by a qualified technical service in line with legal metrology rules. Disconnect power before opening the device and contact a service provider if in doubt. Brand and model names belong to their respective owners and are used only to identify the device.