A&D

GF-L error codes

27 error codes

Review the 27 error and warning messages from the A&D GF-L manufacturer manual, with meanings and fix steps. Device type: precision balance.

Covered models: GF-L

E Overload E indicates an overload on the A&D GF-L. -E Weighing pan error / underload -E indicates a weighing pan error / underload on the A&D GF-L. LowVolt Low supply voltage LowVolt indicates low supply voltage on the A&D GF-L. Error 0 Internal system error Error 0 indicates an internal system error on the A&D GF-L. EC,E11 Weighing stability error EC,E11 indicates a weighing stability error on the A&D GF-L. Error 2 Setting value outside the allowed range Error 2 indicates a setting value outside the allowed range on the A&D GF-L. EC,E20 Calibration weight too heavy EC,E20 indicates a calibration weight that is too heavy on the A&D GF-L. EC,E21 Calibration weight too light EC,E21 indicates a calibration weight that is too light on the A&D GF-L. EC,E00 Communication protocol error EC,E00 indicates a communication protocol error on the A&D GF-L. EC,E01 Undefined command EC,E01 indicates an undefined command on the A&D GF-L. EC,E02 Device not ready to process command EC,E02 indicates the device is not ready to process the command on the A&D GF-L. EC,E03 Communication timeout EC,E03 indicates a communication timeout on the A&D GF-L. EC,E04 Command character length error EC,E04 indicates a command character length error on the A&D GF-L. EC,E06 Command format error EC,E06 indicates a command format error on the A&D GF-L. EC,E07 Parameter value out of range EC,E07 indicates a parameter value out of range on the A&D GF-L. tilt Level check (balance not level) tilt indicates that the A&D GF-L balance is not level according to its spirit level. Lo Sample weight too low Lo indicates that the sample is too light for counting/percent mode on the A&D GF-L. 25 PCS Unit weight too low 25 PCS indicates that the unit weight is too low for piece counting on the A&D GF-L and the sample must be… 50 PCS Unit weight too low 50 PCS indicates that the unit weight is too low for piece counting on the A&D GF-L and the sample must be… 100 PCS Unit weight too low 100 PCS indicates that the unit weight is too low for piece counting on the A&D GF-L and the sample must be… SD Error ECL repeatability error SD Error indicates that repeatability exceeded the limit during the self check on the A&D GF-L. MW Error Minimum weight (reference value) error MW Error indicates that the minimum weight could not be determined with ECL on the A&D GF-L. rtc PF Clock battery error rtc PF indicates that the clock backup battery of the A&D GF-L has run out. Error 3 Internal memory element failure Error 3 indicates an internal memory element failure on the A&D GF-L. Error 5 Weighing sensor error Error 5 indicates a weighing sensor error on the A&D GF-L. Error 8 Internal memory data error Error 8 indicates an internal memory data error on the A&D GF-L. Error 9 Internal memory data error Error 9 indicates an internal memory data error on the A&D GF-L.