Esit

ECI error codes

25 error codes

Review the 25 error and warning messages from the Esit ECI manufacturer manual, with meanings and fix steps. Device type: industrial weighing terminal.

Covered models: ECI

Maximum Load! Maximum load exceeded Error 1 (Maximum Load!) indicates that the measured value exceeds the capacity + 9e limit. Zero Limit! Zero limit exceeded Error 3 (Zero Limit!) indicates that the load on the platform exceeds the zeroing limit and cannot be zeroed. LoadCellError Load cell error Error 5 (LoadCellError) indicates that the load cell may be faulty or there is a connection problem. ADC Data Error! ADC data error Error 6 (ADC Data Error!) indicates that the indicator's ADC (load cell) module is faulty. Coeff.OutofLimit Calibration coefficient out of limit Error 10 (Coeff.OutofLimit) indicates that the coefficient calculated from the calibration is outside the l… Insufficient Load! Calibration load insufficient Error 11 (Insufficient Load!) indicates that the load used in calibration is insufficient. Memory 1 Error Memory 1 error Error 22 (Memory 1 Error) indicates that the memory unit cannot be read or written. Memory 2 Error Memory 2 error Error 24 (Memory 2 Error) indicates that the second memory unit cannot be read or written. PrinterTime.Out Printer timeout Error 31 (PrinterTime.Out) indicates that the printer connection is faulty or no printer is present. Battery Error Clock battery error Error 42 (Battery Error) indicates that the date/time information cannot be read. The manual says to replac… No USB USB memory not inserted Error 50 (No USB) indicates that no USB memory is inserted or detected. No File No file on USB Error 51 (No File) indicates that the required file is not on the USB memory stick. Corrupted File Corrupted file Error 52 (Corrupted File) indicates that the file on the USB is corrupted. The manual says to reload the file. Restart! Restart required Error 53 (Restart!) indicates that the device must be turned off and on again. ShotValueError In-flight value error Error 61 (ShotValueError) indicates that the in-flight (shot) value was entered larger than the target value. LowTareValue Tare value low Error 62 (LowTareValue) indicates that the operation could not be started because the tare value is below t… TargetValue.Excess Target value exceeds capacity Error 64 (TargetValue.Excess) indicates that the target value entered is greater than the capacity. Scale is full Scale full Error 66 (Scale is full) indicates that filling could not be started because the weight on the platform is… ToleranceError! Tolerance error Error 71 (ToleranceError!) indicates that more than the set number of errors occurred in one of the silos d… Disc.Tim.Lap Discharge time exceeded Error 72 (Disc.Tim.Lap) indicates that the weight did not change for the defined time during discharge. ADC ModulError ADC module cannot be read Error 90 (ADC ModulError) indicates that the ADC module cannot be read. Defective Sensor Temperature sensor fault Error 91 (Defective Sensor) indicates that the temperature sensor cannot be read. Mobility Operation not possible due to motion Warning 101 (Mobility) indicates that zeroing or taring could not be done because the weight is not stable. Tare active! Tare active Warning 102 (Tare active!) indicates that zeroing cannot be done while tare is active. Negative Load Cannot tare under negative load Warning 103 (Negative Load) indicates that tare cannot be taken at a negative weight.