Code on display OF DIGI / Teraoka DS-782

Over capacity / load at startup

According to the manual, the message appears when the weight exceeds capacity + 9 divisions (9d), or when there is a product on the platter while the scale is powering on. Weighing is stopped because overload can damage the load cell.

Check it yourself first. If it continues, it needs service.

What should you do?

Try the steps in order.

  1. Remove the product from the platter.
  2. Turn the scale off, make sure the platter is empty, and turn it on again.
  3. Weigh quantities below capacity.
  • Do not place a load heavier than its capacity on the scale.

Possible causes

  • Product heavier than capacity placed on the scale
  • Product or container left on the platter at power-on
  • Shock load placed on the platter

Do you need service?

If OF also appears with an empty platter, contact technical service to check the load cell or A/D circuit.

Models showing this code: DS-782

Source: DIGI / Teraoka official user manual