CAS

CL3000 error codes

25 error codes

Review the 25 error and warning messages from the CAS CL3000 manufacturer manual, with meanings and fix steps. Device type: label printing scale.

Covered models: CL3000-B, CL3000-P

ADM NOT IN Weighing module not responding The scale cannot communicate with the A/D weighing module. AD-Conv A/D conversion error The weighing signal cannot be converted to a digital value. .Chk MEM Err Memory check failed at startup The scale could not complete the memory check during startup. .Key Error Key pressed at startup At startup the scale detected a pressed key or a keypad problem. Zero RNG Err Zero range error At startup the zero point is outside the allowed range. UNSTABLE Weight unstable The scale or the weight on it cannot settle. Overload! Maximum weight exceeded The weight on the platter is above the maximum capacity. Tare Over Tare too high The tare value exceeds the maximum tare allowed by the scale. Already Tare Tare already set A new tare was attempted while a tare is already set. No Tare No tare to clear Tare clearing was attempted while no tare is set. Open TPH Printer head open Printing was attempted while the printer head is open. Paper End Paper end The label or ticket roll in the printer has run out. Press FEED Press FEED The FEED key must be pressed before printing after a paper change. PEEL - OFF Remove printed label The scale is waiting because a printed label has not been removed. Gap Chk Err Wrong label paper The loaded paper does not match the paper type set for the printer. PRINT ERROR Print error An error occurred during printer output. Check weight Check weight The weight is zero when a label print is requested. Check price Check price Print was pressed while the total amount is zero. Check Min WT Below minimum weight The item weight is below the minimum weight of the scale. Remov weight Remove weight There is weight on the platter during a by-piece or by-count sale. Memory full Memory full The sales data buffer is full and no new sale can be made. Data Full !! Data table full The memory for the data table being programmed is full. Net - Err Network error The scale cannot communicate over the network. NO MASTER No master scale The connection to the master scale on the network has been lost. BACKUP FAIL! Backup failed Data could not be backed up to USB memory.