Code on display Err 43 Baykon BX2

Alibi serial number mismatch / cannot print

Printing cannot be done because the Alibi board's serial number does not match. Data output is not possible until the board is registered with the device.

This fault needs a technician.

What should you do?

  • Do not touch the calibration jumper and the legal seal.

Possible causes

  • Alibi board not registered with the device
  • Board or main board replacement

Do you need service?

The manual calls for the Alibi board to be registered with the device. This must be done by technical service.

Models showing this code: BX2

Source: Baykon official user manual · Open manufacturer document