Code on display Err 40 Baykon BX2

Alibi memory error

There is an error in the Alibi memory where weighing records are stored for legal purposes. If an Alibi record cannot be made, legal weighing records cannot be kept.

This fault needs a technician.

What should you do?

You can safely do these while waiting for service.

  1. Turn the device off, wait 30 seconds and turn it on again. If the error continues, contact service.
  • Do not touch the calibration jumper and the legal seal.

Possible causes

  • Parameter 801 set incorrectly
  • Alibi board fault

Do you need service?

According to the manual, parameter 801 must be corrected or the Alibi board must be replaced. These operations require service authorization.

Models showing this code: BX2

Source: Baykon official user manual · Open manufacturer document