Code on display Err 22 Baykon BX2

Tare and memory ınformation error

There is an error in the stored tare, CN, total weight, or in the setpoint (SP), memory tare (PT) and ID information in use. If this information is wrong, tare and total operations can give incorrect results.

Check it yourself first. If it continues, it needs service.

What should you do?

Try the steps in order.

  1. Check the SP, PT and ID values entered and re-enter them if necessary.
  2. Check the tare, CN and total weight values. Delete the incorrect ones and recreate them.
  3. Switch the device off and on again.

Possible causes

  • Incorrectly entered SP, PT or ID value
  • Tare, CN or total weight data corruption

Do you need service?

If Err 22 continues after the values are re-entered, service must check the device memory.

Models showing this code: BX2

Source: Baykon official user manual · Open manufacturer document