Code on display no dAtA Avery Weigh-Tronix ZM305

Remote display not receiving data

The indicator operating as a remote display cannot receive data from the main indicator, so no weight can be shown.

Check it yourself first. If it continues, it needs service.

What should you do?

Try the steps in order.

  1. Check that the main indicator is on.
  2. Check that the communication cable between the two devices is firmly connected at both ends.
  3. Have an authorized person check that the port and communication settings match on both devices.

Possible causes

  • Communication cable broken or loose
  • Main indicator switched off
  • Communication port settings mismatch

Do you need service?

If no data arrives although the cable and settings are correct, the communication hardware must be inspected by service.

Models showing this code: ZM305

Source: Avery Weigh-Tronix official user manual