Low supply voltage and communication data error
E0005 indicates that low supply voltage (E0001) and a communication data error (E0004) occurred at the same time. The error codes are shown added together. Low voltage often triggers communication errors as well.
Check it yourself first. If it continues, it needs service.
What should you do?
Try the steps in order.
- Check the power supply and its connections first.
- Then check the communication cable.
- Check that the baud rate, parity, stop bit and data format settings are the same as on the main device.
Possible causes
- Weak or faulty power supply
- Loose power or communication cable
- Communication settings mismatch
Do you need service?
If the error persists after the supply and communication are corrected, a service check is needed.
Models showing this code: D300
Source: Rinstrum official user manual
Legal notice
The error code explanations and checks on this page are based on manufacturer manuals and are provided for general information only; they do not replace technical service, diagnosis or warranty. The meaning of a code may vary by model, firmware version and configuration.
The decision to carry out any suggested step, and its consequences, rest with the user. Terazibul cannot be held liable for device damage, weighing errors, data loss, commercial loss or any other direct or indirect damage arising from the use of this information.
On legal-for-trade (verified) scales, adjustment and calibration must only be performed by a qualified technical service in line with legal metrology rules. Disconnect power before opening the device and contact a service provider if in doubt. Brand and model names belong to their respective owners and are used only to identify the device.