Fairbanks scales scale error codes

2 series · 22 error codes

On Fairbanks weighing systems, error codes vary by series. Look up load cell, calibration and setpoint warnings for the BlueLine and 3100 Series indicators.

Err01 Load cell signal unstable BlueLine · The measurement signal from the load cell is not stable. Err02 Overload BlueLine · A load above the capacity of the scale was applied. Err03 Negative gross weight BlueLine · The device detected a negative gross weight, which is not permitted. Err04 Out of zero range BlueLine · The current value is outside the permitted range of the zeroing operation. Err05 Sample counting resolution ınsufficient BlueLine · The sample weight used for piece counting does not provide sufficient accuracy. Err06 Input signal too high BlueLine · The input signal from the weighing system is above the permitted level. Err08 Calibration range error BlueLine · The calibration value is outside the permitted negative limit. Err09 Calibration signal too low BlueLine · The measurement signal received during calibration does not reach the required level. Err10 Calibration point order error BlueLine · The value of the next calibration point was detected as lower than the previous point. Err14 Setpoint order error BlueLine · The second setpoint value was set lower than the first setpoint value. Err97 Operation blocked due to legal approval BlueLine · An operation not permitted on an NTEP/approved system was attempted. Err01 Load cell signal unstable 3100 Series · The measurement signal from the load cell is not stable. Err02 Overload 3100 Series · A load above the capacity of the scale was applied. Err03 Negative gross weight 3100 Series · The device detected a negative gross weight, which is not permitted. Err04 Out of zero range 3100 Series · The current value is outside the permitted range of the zeroing operation. Err05 Sample counting resolution ınsufficient 3100 Series · The sample weight used for piece counting does not provide sufficient accuracy. Err06 Input signal too high 3100 Series · The input signal from the weighing system is above the permitted level. Err08 Calibration range error 3100 Series · The calibration value is outside the permitted negative limit. Err09 Calibration signal too low 3100 Series · The measurement signal received during calibration does not reach the required level. Err10 Calibration point order error 3100 Series · The value of the next calibration point was detected as lower than the previous point. Err14 Setpoint order error 3100 Series · The second setpoint value was set lower than the first setpoint value. Err97 Operation blocked due to legal approval 3100 Series · An operation not permitted on an NTEP/approved system was attempted.